RE: Update: ES40: CPU1 VIO warn
Maulis Adam <maulis@ludens.elte.hu>
Szia,
> > Alphaserver ES40 leirasok:
> > http://h18002.www1.hp.com/alphaserver/archive/es40/index.html
>
> Ez ismeros, bar nekem Service Manual kellene.
> (Mar ha letezik. Regebbi Alphaknal mintha lattam
> volna.) Csak felteszem, az piszokul nem publikus...
mintha egyszer letoltottem volna valahonnan, de most nem talalom,
honnan.
Hm-hm.
Van egy fail-safe loader jumper az alaplapon:
J22 jumper, kozel a PCI hatlaphoz. Ha ez 2-3 kozott van
kapcsolva, akkor failsafe loader uzemmod. nem ide tartozik,
de egy fontos info, tedd el :-)
"CPU1 VIO warn"
Table 66 RMC Warning Messages
Message Meaning
PSn failed Power supply failed. "n" is 0, 1, or 2.
OverTemp Warning System temperature is near the high threshold.
Fann failed Fan failed. "n" is 0 through 6.
PCI door opened Cover to PCI card cage is off. Reinstall cover.
Fan door opened Cover to main fan area (fans 5 and 6) is off.
Reinstall cover.
3.3V bulk warn Power supply voltage is over or under threshold.
5V bulk warn Power supply voltage is over or under threshold.
12V bulk warn Power supply voltage is over or under threshold.
12V bulk warn Power supply voltage is over or under threshold.
VTERM warn Voltage regulator is over or under threshold.
CTERM warn Voltage regulator is over or under threshold.
CPUn VCORE warn CPU core voltage is over or under threshold.
"n" is 0, 1, 2, or 3.
CPUn VIO warn I/O voltage on CPU is over or under threshold.
"n" is 0, 1, 2, or 3.
............
AlphaServer ES40 RMC
The RMC in an AlphaServer ES40 has the following functions:
ˇ Monitors the system environmental conditions
- Voltages and fan speeds monitored by LM78 chips on the CPB
............
CPB: PCI backplane
> Nagyak
Ennyit tudtam segiteni.
Udv,
Adam